PRODUCT  DISPLAY产品展示

PRODUCT DISPLAY
产品详情
+
According to different detector configuration, carrier gas and hydrogen can be built in and low noise air micro pump. Pressure-resistant shock-proof storm box, can withstand a drop of up to 1 m height;
productDetail

Portable Gas Chromatograph

According to different detector configuration, carrier gas and hydrogen can be built in and low noise air micro pump

Pressure-resistant shock-proof storm box, can withstand a drop of up to 1 m height;

Integrated design of the whole machine system, without any need for external support equipment, to achieve portability in the real sense.

Built-in large screen LCD with Windows operating system without additional laptop.

Three detectors including FID, TCD and PDD can be equipped at the same time.

Technical data:

Detector can be equipped

Hydrogen flame ionization detector

Thermal conductive detector

Pulse discharge of the helium ionization detector

Detector data

Hydrogen flame ionization   detector

Thermal conductive detector

Pulse discharge of the helium   ionization detector

Cylinder-type collector pole structure, quartz nozzle, extremely high   response

Semi-diffusion-type structure

Discharge   mode: pulse discharge

Automatic ignition;

stabilization time: ten minutes

Power supply adopts constant current control


(Test limit)8×10-12gsOrthohexadetane   / isooctane

 

Sensitivity10000mV·mlmgBenzene

(Test   limit):≤1.0×10-10g/ml

Baseline noise2×10-13A

 

Baseline noise20μV

Baseline   noise0.1mv

Baseline drift

2×10-12A/30min

Baseline drift

100μV/30min

Baseline drift

0.5mv/30min

Linearity106

Linearity104

Linearity106

 

1、  Temperature control index

Temperature   control  parts

Temperature   control range

Temperature   control accuracy

Column   box

8 ℃ ~400 ℃ at room temperature

±0.1

Hydrogen   flame ionization detector

8 ~400 at room temperature

±0.1

Thermal   conductive detector

8 ~400 at room temperature

±0.1

Pulse   discharge of the helium ionization detector

8 ~350 at room temperature

±0.1

Ni   catalyst converter

8 ~400 at room temperature

±0.1

2、  Column box parameters

Temperature control accuracy

8 ~400   at room temperature   ±0.1

Program rise order

eight

Program heating rate

1-40

constant temperature retention time

for each order

0-655min1min

3、  chromatograph workstation

Acquisition   card

Built-in, RS232   or USB port connection

High-precision   data acquisition

24 bit high   precision A/D data acquisition card, resolution±1uv

channel

2

Level range

-2v+2v

Integration   sensitivity

1μv·sec

Linearity

106

Linearity

<±0.1%

Reproducibility

0.06


Technical characteristics

Highly integrated all-in-one design

The GC-9760 portable gas chromatograph has a built-in gas source, industrial control computer and workstation, with no need for external gas source and computer. The outer box adopts the original imported storm box, which can withstand a drop of a height more than 1 m.

    Computer feedback control technology is adopted to realize digital operation of the instrument.

The analysis parameters of GC-9760 portable gas chromatograph, including the setting or display of carrier gas pressure, sample pressure, temperature, etc., are performed through the workstation. The operation is simple and the analysis conditions can be grasped in real time.

Adopt the central cutting technology to realize the high automation of the instruments

GC-9760 portable gas chromatograph adopts the multi-valve and multi-column center cutting and reverse-flushing technology, and automatically controls the sample inlet, switching, cutting and reverse-flushing processes through the time program set by the workstation, and the separation of complex sample entry can be completed at one time.

Digital electronic zero tuning technology to enhance the anti-interference ability of the instrument.

The detector signal zero tuning of GC-9760 portable gas chromatograph adopts the electronic zero tuning technology, and uses the high-precision digital circuit for base flow compensation, to realize the electronic tuning of the output signal level, reduce the parasitic parameters, so it has a strong anti-interference capability.

Automatic gas cut-off protection function to ensure the safe operation of the detector.

   


GC-9760 portable gas chromatograph has an intelligent gas cut-off protection function, which automatically cuts off the detector voltage to protect the detector from dama.